{"id":57300,"date":"2011-06-30T11:34:00","date_gmt":"2011-06-30T11:34:00","guid":{"rendered":"https:\/\/nationalairfiltrationassociation.growthzonesites.com\/?p=57300"},"modified":"2023-03-01T11:35:00","modified_gmt":"2023-03-01T11:35:00","slug":"pressure-drop-and-electrical-cost-considerations-in-filter-performance","status":"publish","type":"post","link":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/","title":{"rendered":"Pressure Drop and Electrical Cost Considerations in Filter Performance"},"content":{"rendered":"\n<p>Running a filter to the final manufacturer&#8217;s recommended pressure reading could mean you are squeezing every last penny of cost from the filter. It could also mean you just wasted more money in energy costs because of the extra time it takes to heat or cool your facility due to lower supply velocities. So how do you know when it is the optimal time to change your filters?<\/p>\n<p>The following equation will apply:<\/p>\n<blockquote><p>Energy Cost = HP x ($\/KwHr) x Hours\/0.746<\/p>\n<p>Where HP (motor horsepower) = Average DP x CFM\/Fan Efficiency x 0.001173<\/p><\/blockquote>\n<p>This is graphically represented by:<\/p>\n<figure id=\"attachment_881\" aria-describedby=\"caption-attachment-881\"><img decoding=\"async\" title=\"016_image1\" src=\"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg\" alt=\"\" width=\"499\" height=\"480\"><figcaption id=\"caption-attachment-881\">Figure 13.3 Optimum Final Pressure Drop NAFA Guide to Air Filtration, 3rd Edition 2001, National Air Filtration Association, page 13.2 &#8211; 13.6<\/figcaption><\/figure>\n<p>By utilizing this formula, you can determine where the optimal change out time is for your particular filtration system based on your specific electric rates, hours of operation and type of filter.<\/p>\n<h3>References:<\/h3>\n<p><sup>1<\/sup><em>NAFA Guide to Air Filtration<\/em>, 3rd Edition 2001, National Air Filtration Association, page 13.2- 13.6<\/p>\nPressure Drop; Fall 2002 issue of&nbsp;<em>Air Media<\/em><br>\nAuthor(s): Dean Arnold, Kimberly Clark Corporation; NAFA Staff\n","protected":false},"excerpt":{"rendered":"<p>Running a filter to the final manufacturer&#8217;s recommended pressure reading could mean you are squeezing every last penny of cost from the filter. It could also mean you just wasted more money in energy costs because of the extra time it takes to heat or cool your facility due to lower supply velocities. So how&hellip;<\/p>\n","protected":false},"author":4339,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"tpl-full-width.php","format":"standard","meta":[],"categories":[1],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v18.2.1 (Yoast SEO v18.4.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Pressure Drop and Electrical Cost Considerations in Filter Performance - National Air Filtration Association<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pressure Drop and Electrical Cost Considerations in Filter Performance\" \/>\n<meta property=\"og:description\" content=\"Running a filter to the final manufacturer&#8217;s recommended pressure reading could mean you are squeezing every last penny of cost from the filter. It could also mean you just wasted more money in energy costs because of the extra time it takes to heat or cool your facility due to lower supply velocities. So how&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/\" \/>\n<meta property=\"og:site_name\" content=\"National Air Filtration Association\" \/>\n<meta property=\"article:published_time\" content=\"2011-06-30T11:34:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-01T11:35:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"jweiss@manageassociations.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.nafahq.org\/#website\",\"url\":\"https:\/\/www.nafahq.org\/\",\"name\":\"National Air Filtration Association\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.nafahq.org\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg\",\"contentUrl\":\"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#webpage\",\"url\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/\",\"name\":\"Pressure Drop and Electrical Cost Considerations in Filter Performance - National Air Filtration Association\",\"isPartOf\":{\"@id\":\"https:\/\/www.nafahq.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#primaryimage\"},\"datePublished\":\"2011-06-30T11:34:00+00:00\",\"dateModified\":\"2023-03-01T11:35:00+00:00\",\"author\":{\"@id\":\"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.nafahq.org\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pressure Drop and Electrical Cost Considerations in Filter Performance\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43\",\"name\":\"jweiss@manageassociations.com\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.nafahq.org\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g\",\"caption\":\"jweiss@manageassociations.com\"},\"url\":\"https:\/\/www.nafahq.org\/author\/jeanne-weiss-3\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Pressure Drop and Electrical Cost Considerations in Filter Performance - National Air Filtration Association","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/","og_locale":"en_US","og_type":"article","og_title":"Pressure Drop and Electrical Cost Considerations in Filter Performance","og_description":"Running a filter to the final manufacturer&#8217;s recommended pressure reading could mean you are squeezing every last penny of cost from the filter. It could also mean you just wasted more money in energy costs because of the extra time it takes to heat or cool your facility due to lower supply velocities. So how&hellip;","og_url":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/","og_site_name":"National Air Filtration Association","article_published_time":"2011-06-30T11:34:00+00:00","article_modified_time":"2023-03-01T11:35:00+00:00","og_image":[{"url":"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg"}],"twitter_card":"summary_large_image","twitter_misc":{"Written by":"jweiss@manageassociations.com","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.nafahq.org\/#website","url":"https:\/\/www.nafahq.org\/","name":"National Air Filtration Association","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.nafahq.org\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#primaryimage","inLanguage":"en-US","url":"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg","contentUrl":"https:\/\/www.nafahq.org\/wp-content\/uploads\/016_image11.jpg"},{"@type":"WebPage","@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#webpage","url":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/","name":"Pressure Drop and Electrical Cost Considerations in Filter Performance - National Air Filtration Association","isPartOf":{"@id":"https:\/\/www.nafahq.org\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#primaryimage"},"datePublished":"2011-06-30T11:34:00+00:00","dateModified":"2023-03-01T11:35:00+00:00","author":{"@id":"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43"},"breadcrumb":{"@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/pressure-drop-and-electrical-cost-considerations-in-filter-performance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.nafahq.org\/"},{"@type":"ListItem","position":2,"name":"Pressure Drop and Electrical Cost Considerations in Filter Performance"}]},{"@type":"Person","@id":"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43","name":"jweiss@manageassociations.com","image":{"@type":"ImageObject","@id":"https:\/\/www.nafahq.org\/#personlogo","inLanguage":"en-US","url":"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g","caption":"jweiss@manageassociations.com"},"url":"https:\/\/www.nafahq.org\/author\/jeanne-weiss-3\/"}]}},"_links":{"self":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts\/57300"}],"collection":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/users\/4339"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/comments?post=57300"}],"version-history":[{"count":3,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts\/57300\/revisions"}],"predecessor-version":[{"id":57306,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts\/57300\/revisions\/57306"}],"wp:attachment":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/media?parent=57300"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/categories?post=57300"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/tags?post=57300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}