{"id":57404,"date":"2011-06-30T11:50:00","date_gmt":"2011-06-30T11:50:00","guid":{"rendered":"https:\/\/nationalairfiltrationassociation.growthzonesites.com\/?p=57404"},"modified":"2023-03-01T11:51:10","modified_gmt":"2023-03-01T11:51:10","slug":"cleanrooms-minimum-testing-criteria","status":"publish","type":"post","link":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/","title":{"rendered":"Cleanrooms, Minimum Testing Criteria"},"content":{"rendered":"\n<p>(Ed. Note: The largest number of cleanrooms is divided between the semi-conductor industry, driven by increased yield (or decreased cull rates), and the pharmaceutical\/ medical device industry driven by health-related concerns of not causing death or illness to the public along with FDA regulatory concerns. In this article, Mr. Brande presents his views on what the absolute minimum testing criteria should be for a cleanroom to be &#8220;certified.&#8221;)<\/p>\n<p>There are five tests and\/or calculations that must be performed in order to prove four objectives that qualify a cleanroom as functional:<\/p>\n<h3>One<\/h3>\n<p>Demonstrate that the controlled area meets the desired classification (Class ISO 5; Class ISO 6; Class ISO 7 or Class ISO 8).<\/p>\n<em>Required Test:<\/em><br>\nRoom classifications according to ISO 14644-1, or the now defunct Federal Standard 209E, to establish that the desired room class has been met.\n<h3>Two<\/h3>\n<p>Demonstrate that no particulate will enter the controlled area by way of the supply air mechanical system.<\/p>\n<em>Required Test:<\/em><br>\nIntegrity testing of the HEPA filtered supply (or exhaust) air with an oil aerosol (ambient challenge not accepted here) to show no bypass of airflow and potentially detrimental particulate.\n<h3>Three<\/h3>\n<p>Demonstrate that no particulate will enter (positive) or exit (negative) the controlled area due to construction (wall and\/or ceiling utility penetrations, mouse holes and threshold gaps).<\/p>\n<em>Required Test:<\/em><br>\nDifferential pressures will indicate that both direction and magnitude of static pressures is sufficient to control migration of particulate from one controlled area to another (or even an uncontrolled area).\n<h3>Four<\/h3>\n<p>Demonstrate that, should there be an episode of particulate generation within the controlled area, the design of the room will handle the particulate in a &#8220;controlled&#8221; and timely manner.<\/p>\n<em>Required Test:<\/em><br>\nControlled area volumes (sometimes recorded in the form of velocities and converted) and subsequently the room air exchange rates are used to determine if there is sufficient airflow into a controlled area to neutralize (dilute) any short term potential source of particulate in an area and also maintain the required static pressures.\n<h3>Five<\/h3>\n<em>Required Test:<\/em><br>\nFinally, air flow visualization (a picture is worth a thousand words) for the definitive answer as to whether a controlled area can truly control particulate.\n<blockquote><p>&#8220;If I could perform only one test in a Class ISO 5 (Class 100) environment, this would be my choice. In my opinion, more pertinent information can be derived from this test than all of the other standard tests listed in either IEST-RP-CC006.3 or ISO 14644 Part 3.&#8221;<\/p><\/blockquote>\n<p>Note: In areas Class ISO 6 (Class 1000) and higher, this test takes on another form called room recovery and is not quite so &#8216;visual&#8217;. Bear in mind, that both tests are considered destructive in terms of trying to maintain sterility.<\/p>\nCleanrooms; Winter2006 issue of&nbsp;<em>Air Media<\/em><br>\nAuthor(s): David Brande, Contamination Control Technologies, Inc.\n","protected":false},"excerpt":{"rendered":"<p>(Ed. Note: The largest number of cleanrooms is divided between the semi-conductor industry, driven by increased yield (or decreased cull rates), and the pharmaceutical\/ medical device industry driven by health-related concerns of not causing death or illness to the public along with FDA regulatory concerns. In this article, Mr. Brande presents his views on what&hellip;<\/p>\n","protected":false},"author":4339,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"tpl-full-width.php","format":"standard","meta":[],"categories":[1],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v18.2.1 (Yoast SEO v18.4.1) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Cleanrooms, Minimum Testing Criteria - National Air Filtration Association<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cleanrooms, Minimum Testing Criteria\" \/>\n<meta property=\"og:description\" content=\"(Ed. Note: The largest number of cleanrooms is divided between the semi-conductor industry, driven by increased yield (or decreased cull rates), and the pharmaceutical\/ medical device industry driven by health-related concerns of not causing death or illness to the public along with FDA regulatory concerns. In this article, Mr. Brande presents his views on what&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/\" \/>\n<meta property=\"og:site_name\" content=\"National Air Filtration Association\" \/>\n<meta property=\"article:published_time\" content=\"2011-06-30T11:50:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-01T11:51:10+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"jweiss@manageassociations.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.nafahq.org\/#website\",\"url\":\"https:\/\/www.nafahq.org\/\",\"name\":\"National Air Filtration Association\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.nafahq.org\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/#webpage\",\"url\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/\",\"name\":\"Cleanrooms, Minimum Testing Criteria - National Air Filtration Association\",\"isPartOf\":{\"@id\":\"https:\/\/www.nafahq.org\/#website\"},\"datePublished\":\"2011-06-30T11:50:00+00:00\",\"dateModified\":\"2023-03-01T11:51:10+00:00\",\"author\":{\"@id\":\"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.nafahq.org\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cleanrooms, Minimum Testing Criteria\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43\",\"name\":\"jweiss@manageassociations.com\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.nafahq.org\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g\",\"caption\":\"jweiss@manageassociations.com\"},\"url\":\"https:\/\/www.nafahq.org\/author\/jeanne-weiss-3\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Cleanrooms, Minimum Testing Criteria - National Air Filtration Association","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/","og_locale":"en_US","og_type":"article","og_title":"Cleanrooms, Minimum Testing Criteria","og_description":"(Ed. Note: The largest number of cleanrooms is divided between the semi-conductor industry, driven by increased yield (or decreased cull rates), and the pharmaceutical\/ medical device industry driven by health-related concerns of not causing death or illness to the public along with FDA regulatory concerns. In this article, Mr. Brande presents his views on what&hellip;","og_url":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/","og_site_name":"National Air Filtration Association","article_published_time":"2011-06-30T11:50:00+00:00","article_modified_time":"2023-03-01T11:51:10+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"jweiss@manageassociations.com","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.nafahq.org\/#website","url":"https:\/\/www.nafahq.org\/","name":"National Air Filtration Association","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.nafahq.org\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/#webpage","url":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/","name":"Cleanrooms, Minimum Testing Criteria - National Air Filtration Association","isPartOf":{"@id":"https:\/\/www.nafahq.org\/#website"},"datePublished":"2011-06-30T11:50:00+00:00","dateModified":"2023-03-01T11:51:10+00:00","author":{"@id":"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43"},"breadcrumb":{"@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.nafahq.org\/2011\/06\/30\/cleanrooms-minimum-testing-criteria\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.nafahq.org\/"},{"@type":"ListItem","position":2,"name":"Cleanrooms, Minimum Testing Criteria"}]},{"@type":"Person","@id":"https:\/\/www.nafahq.org\/#\/schema\/person\/db094c32d2c3fbc340fc862e2f66fb43","name":"jweiss@manageassociations.com","image":{"@type":"ImageObject","@id":"https:\/\/www.nafahq.org\/#personlogo","inLanguage":"en-US","url":"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a4cfd5b0b48d43a68423288acb025fef?s=96&d=mm&r=g","caption":"jweiss@manageassociations.com"},"url":"https:\/\/www.nafahq.org\/author\/jeanne-weiss-3\/"}]}},"_links":{"self":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts\/57404"}],"collection":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/users\/4339"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/comments?post=57404"}],"version-history":[{"count":3,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts\/57404\/revisions"}],"predecessor-version":[{"id":57410,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/posts\/57404\/revisions\/57410"}],"wp:attachment":[{"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/media?parent=57404"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/categories?post=57404"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.nafahq.org\/wp-json\/wp\/v2\/tags?post=57404"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}